Near Miss -. CHIRP report M2642 came from a crew member cleaning and painting engine-room bilges during an extensive refit.
They were crouched at the bottom of a 6 ft bilge sump, using acetone to degrease the surfaces. The report states that vapour accumulated and oxygen was rapidly displaced. The crew member was wearing the VOC mask required by company procedures, so smell provided no warning of the changing atmosphere.
The first sign was a strong fight-or-flight sensation. They climbed out and called for help by radio.
This can occur during routine solvent work in bilges, tanks and other low spaces. PPE may address exposure to vapour while leaving oxygen levels unknown to the person doing the job.
CHIRP identifies body-worn gas detection as one of the missing safeguards. It gives the worker an atmospheric reading rather than leaving symptoms as the first warning.
For solvent work in low spaces on your vessel, is a body-worn gas detector issued before the task starts?